Institutional Repository of Key Laboratory of Marine Environmental Corrosion and Bio-fouling, IOCAS
Direct immobilisation of antibodies on a bioinspired architecture as a sensing platform | |
Wan, Yi1,2; Zhang, Dun1; Wang, Yi1; Qi, Peng1,2; Hou, Baorong1; Zhang, D (reprint author), Chinese Acad Sci, Inst Oceanol, Key Lab Corros Sci, 7 Nanhai Rd, Qingdao 266071, Shandong, Peoples R China | |
2011-01-15 | |
发表期刊 | BIOSENSORS & BIOELECTRONICS |
ISSN | 0956-5663 |
卷号 | 26期号:5页码:2595-2600 |
文章类型 | Article |
摘要 | A sensitive and selective immunosensor for the nonlabeled detection of sulfate-reducing bacteria (SRB) is constructed using a self-polymerised polydopamine film as the immobilisation platform. Self-polymerisation of dopamine is used as a powerful approach for applying multifunctional coatings onto the surface of a gold electrode. The polydopamine film is used not only as the immobilisation platform, but also as a cross-linker reagent for the immobilisation of the anti-SRB antibody. The polydopamine film is loaded with a high density of anti-SRB antibodies linked to the substrate to obtain high response signals. The formation and fabrication of the biosensor and the quantification of antibody anchoring are monitored, and SRB detection is performed by either quartz crystal microbalance (QCM) or electrochemical impedance spectroscopy (EIS). After modeling the impedance Nyquist plots of the SRB/anti-SRB/polydopamine/gold electrode for increasing concentrations of SRB, the electron transfer resistance (R(ct)) is used as a measure of immunocomplex binding. The R(ct) is correlated with the concentration of bacterial cells in the range of 1.8 x 10(2) to 1.8 x 10(6) CFU mL(-1); the detection limit is 50 CFU mL(-1). This work demonstrates a new immobilisation platform for the development of a sensitive and label-less impedimetric and piezoelectric immunosensor. This immunosensor may be broadly applied in clinical diagnoses and the monitoring of water environmental pollution. The method proposed is distinct in its ease of application, use of a simple protocol, and mild reaction conditions. These allow it to be applied to a wide variety of materials. (C) 2010 Elsevier B.V. All rights reserved.; A sensitive and selective immunosensor for the nonlabeled detection of sulfate-reducing bacteria (SRB) is constructed using a self-polymerised polydopamine film as the immobilisation platform. Self-polymerisation of dopamine is used as a powerful approach for applying multifunctional coatings onto the surface of a gold electrode. The polydopamine film is used not only as the immobilisation platform, but also as a cross-linker reagent for the immobilisation of the anti-SRB antibody. The polydopamine film is loaded with a high density of anti-SRB antibodies linked to the substrate to obtain high response signals. The formation and fabrication of the biosensor and the quantification of antibody anchoring are monitored, and SRB detection is performed by either quartz crystal microbalance (QCM) or electrochemical impedance spectroscopy (EIS). After modeling the impedance Nyquist plots of the SRB/anti-SRB/polydopamine/gold electrode for increasing concentrations of SRB, the electron transfer resistance (R(ct)) is used as a measure of immunocomplex binding. The R(ct) is correlated with the concentration of bacterial cells in the range of 1.8 x 10(2) to 1.8 x 10(6) CFU mL(-1); the detection limit is 50 CFU mL(-1). This work demonstrates a new immobilisation platform for the development of a sensitive and label-less impedimetric and piezoelectric immunosensor. This immunosensor may be broadly applied in clinical diagnoses and the monitoring of water environmental pollution. The method proposed is distinct in its ease of application, use of a simple protocol, and mild reaction conditions. These allow it to be applied to a wide variety of materials. (C) 2010 Elsevier B.V. All rights reserved. |
关键词 | Dopamine Impedimetric Immunosensor Sensing Platform Bioinspired Architecture Bacteria Detection |
学科领域 | Biophysics ; Biotechnology & Applied Microbiology ; Chemistry ; Electrochemistry ; Science & Technology - Other Topics |
DOI | 10.1016/j.bios.2010.11.013 |
URL | 查看原文 |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000286904400130 |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.qdio.ac.cn/handle/337002/11437 |
专题 | 海洋环境腐蚀与生物污损重点实验室 |
通讯作者 | Zhang, D (reprint author), Chinese Acad Sci, Inst Oceanol, Key Lab Corros Sci, 7 Nanhai Rd, Qingdao 266071, Shandong, Peoples R China |
作者单位 | 1.Chinese Acad Sci, Inst Oceanol, Key Lab Corros Sci, Qingdao 266071, Shandong, Peoples R China 2.Chinese Acad Sci, Grad Sch, Beijing 100039, Peoples R China |
第一作者单位 | 中国科学院海洋研究所 |
推荐引用方式 GB/T 7714 | Wan, Yi,Zhang, Dun,Wang, Yi,et al. Direct immobilisation of antibodies on a bioinspired architecture as a sensing platform[J]. BIOSENSORS & BIOELECTRONICS,2011,26(5):2595-2600. |
APA | Wan, Yi,Zhang, Dun,Wang, Yi,Qi, Peng,Hou, Baorong,&Zhang, D .(2011).Direct immobilisation of antibodies on a bioinspired architecture as a sensing platform.BIOSENSORS & BIOELECTRONICS,26(5),2595-2600. |
MLA | Wan, Yi,et al."Direct immobilisation of antibodies on a bioinspired architecture as a sensing platform".BIOSENSORS & BIOELECTRONICS 26.5(2011):2595-2600. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
Direct immobilisatio(523KB) | 限制开放 | -- | 浏览 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论