Application of calcite, Mg-calcite, and dolomite as Raman pressure sensors for high-pressure, high-temperature studies | |
Yuan, Xueyin1; Xiong, Xin1; Zhang, Guoliang2,3; Mayanovic, Robert A.4 | |
2020-05-13 | |
发表期刊 | JOURNAL OF RAMAN SPECTROSCOPY |
ISSN | 0377-0486 |
页码 | 12 |
通讯作者 | Yuan, Xueyin(xueyinyuan@live.com) |
摘要 | The Raman spectra of calcite, Mg-calcite, and dolomite were measured under ambient and high pressure-temperature (P-T) conditions using a hydrothermal diamond anvil cell, for the purpose of developing new pressure sensors suited for experiments investigating the physicochemical properties of carbonate minerals. By fitting the Raman vibrational frequencies as functions of pressure and temperature, pressure (P, in MPa) can be determined from relative frequency shifts (in cm(-1)) of the symmetric stretching (nu(1)) and librational (nu(L)) lattice vibrations of calcite: P = 229(1) x (nu(1 calcite, HP) - nu(1 calcite, ref)), P = 162(1) x (nu(L calcite, HP) - nu(L calcite, ref)), or from the translational (nu(T)) and librational (nu(L)) lattice vibrations of dolomite: P = 371(3) x [(nu(L dolomite, HP) - nu(T dolomite, HP)) - (nu(L dolomite, ref) - nu(T dolomite, ref))], where nu(ref) is the value under ambient P-T conditions. Under elevated temperatures, correction for the effect of temperature (T, in degrees C) on the Raman frequency shifts can be accomplished through nu(1 calcite, HT) = nu(1 calcite, ref) - 6.8(5) x 10(-6) x T-2-0.0051(3) x T + 0.12, nu(L calcite, HT) = nu(L calcite, ref) - 1.07(12) x 10(-5) x T-2-0.00341(7) x T + 0.76, nu(L dolomite, HT) - nu(T dolomite, HT) = (nu(L dolomite, ref) - nu(T dolomite, ref)) - 0.0198(3) x T + 0.45. Application of the calcite and dolomite Raman pressure sensors should be made on condition that no phase transitions or breakdown reactions occur under high P-T conditions, with errors of +/- 50 MPa and +/- 5% at pressures below and above 1.0 GPa, respectively. Results from an additional experiment showed that pressures determined using alternate Raman pressure calibration methods were self-consistent and in excellent agreement with the results determined using the nu(1) Raman peak shifts of aragonite. |
关键词 | calcite dolomite Mg-calcite pressure calibration Raman pressure sensor |
DOI | 10.1002/jrs.5893 |
收录类别 | SCI |
语种 | 英语 |
资助项目 | National Natural Science Foundation of China[91858206] ; National Natural Science Foundation of China[41702039] |
WOS研究方向 | Spectroscopy |
WOS类目 | Spectroscopy |
WOS记录号 | WOS:000531911400001 |
出版者 | WILEY |
引用统计 | |
文献类型 | 期刊论文 |
条目标识符 | http://ir.qdio.ac.cn/handle/337002/167443 |
专题 | 海洋地质与环境重点实验室 深海极端环境与生命过程研究中心 |
通讯作者 | Yuan, Xueyin |
作者单位 | 1.Chinese Acad Geol Sci, Inst Mineral Resources, MNR Key Lab Metallogeny & Mineral Assessment, Beijing 100037, Peoples R China 2.Chinese Acad Sci, Key Lab Marine Geol & Environm, Qingdao, Peoples R China 3.Chinese Acad Sci, Ctr Deep Sea Res, Inst Oceanol, Qingdao, Peoples R China 4.Missouri State Univ, Dept Phys Astron & Mat Sci, Springfield, MO USA |
推荐引用方式 GB/T 7714 | Yuan, Xueyin,Xiong, Xin,Zhang, Guoliang,et al. Application of calcite, Mg-calcite, and dolomite as Raman pressure sensors for high-pressure, high-temperature studies[J]. JOURNAL OF RAMAN SPECTROSCOPY,2020:12. |
APA | Yuan, Xueyin,Xiong, Xin,Zhang, Guoliang,&Mayanovic, Robert A..(2020).Application of calcite, Mg-calcite, and dolomite as Raman pressure sensors for high-pressure, high-temperature studies.JOURNAL OF RAMAN SPECTROSCOPY,12. |
MLA | Yuan, Xueyin,et al."Application of calcite, Mg-calcite, and dolomite as Raman pressure sensors for high-pressure, high-temperature studies".JOURNAL OF RAMAN SPECTROSCOPY (2020):12. |
条目包含的文件 | ||||||
文件名称/大小 | 文献类型 | 版本类型 | 开放类型 | 使用许可 | ||
jrs.5893.pdf(2457KB) | 期刊论文 | 出版稿 | 限制开放 | CC BY-NC-SA | 浏览 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论